The CeraFuse Coating Process
CeraFuse Applications
Adhesion
Specimen #
Deposit Thickness
Fracture Area (mm2)
Tensile Force (kg) Bond Strength (MPA)
Comments
1
.001 - .002"
461.86
505 10.78
Epoxy
Failure at
Deposit
Interface
2
.0025 - .0035" 481.00 1380 28.12 Epoxy
Failure
3
.004 - .005" 490.87 1487 29.70 Epoxy
Failure
Characteristics of the Deposit
CeraHone.com
Contact Us
Press Release
Deposit Hardness - KNOOP - 100 gram load
Substrate
A1 2024-T4
A1 6061-T6
A1 7075-T651
CeraFuse MCC-631
1772 Kn100
1660 Kn100
1509 Kn100
Hard Anodize
468 Kn100 493 Kn100 506 Kn100
Electrical Resistance
Substrate Alloy
Deposit Thickness
Deposit Condition
Breakdown Voltage-DC Breakdown Voltage-AC
A1 2024-T6
.001 - .0015"
As Deposited
500 - 800
300 - 700
A1 2024-T3
.003 - .0035"
As Deposited
300 - 400
520 - 650
A1 6061-T6
.001 - .0015"
.0025 - .003"
.0035 - .004"
Impregnated - Hi Therm BC - 346A
3000 - 3500
4200 - 4500
5500 - 7000
None to 3000
None to 3000
None to 3000
Testing performed per ASTM-D-3755-86. Testing conducted at OMEGA Metal Laboratories.
Corrosion Resistance
Specimen #
Deposit
Thickness
Hours in Test Until Initial Evidence of Corrosion
Comments
19
.001 - .0015"
1268
Deposit surface polished before testing
20
.002 - .0025" 1436 Deposit surface polished before testing
21
.004 - .0045" 1700 Deposit surface polished before testing
22
.001 - .0015" None at 1700 Deposit surface polished and impregnated before testing
23
.002 - .0025" None at 1700 Deposit surface polished and impregnated before testing
24
.004 - .0045" None at 1700 Deposit surface polished and impregnated before testing
Corrosion testing per ASTM B-117. The initial duration of the test (per specification) was 336 hours. Since no evidence of corrosion was present at that point, the specimen was cleaned and the test continued with examination intervals of 24 hours. Substrate material is A1 6061 - T6. Testing conducted at OMEGA Metal Laboratories and QC Metallurgical Laboratories.
Taber Abraser Test Data
Sample I.D.
Wear Index (10,000 Cycles)
Wear Index (20,000 Cycles)
Wear Index (30,000 Cycles) Wear Index (40,000 Cycles)
Wear Index (50,000 Cycles)
1-A
9.49 mg
4.49 mg
2.38 mg 1.95 mg
1.70 mg
2-A
8.95 mg 4.02 mg 2.44 mg 1.85 mg 1.77 mg
3-L
2.38 mg 1.52 mg 1.64 mg 1.27 mg 1.32 mg
4-L
1.79 mg 1.14 mg 1.45 mg 1.26 mg 1.23 mg
Testing performed per MIL-A8625F. Testing conducted at QC Metallurgical Laboratories. Substrate material is A1 6061-T6.
Wear Index calculated as follows:
WI (wear index)=(A-B)x 1000/C
A=Weight of specimen before abrasion cycle B=Weight of specimen after abrasion cycle C=Number of abrasion cycles recorded
Samples 1-A and 2-A were processed in the "as-deposited" condition. Samples 3-L and 4-L were finished to Ra 16-24 prior to testing.
Note that Taber Abraser test results on CeraFuse™ microarc oxidation deposits can be somewhat misleading if taken only at face value. It is apparent that the "layers" of the deposit, even though they appear homogenous, abrade at different rates during a Taber test. As might be expected, the outer or granular layer abrades very rapidly. As that layer is removed and the test apparatus contacts the more dense, functional layer, the deposit exhibits a marked reduction in weight loss per 1000 cycles.